Standard Configuration:
Step 1: Connect Data output 1 from the 931 Controller to the data input of
the left channel 921 Mono Decoding Computer.
Step 2: Connect ClockLink output 3 from the 931 Controller to the ClockLink
input of the left channel 921 Mono Decoding Computer.
Step 3: Connect Data output 2 from the 931 Controller to the data input of
the right channel 921 Mono Decoding Computer.
Step 4: Connect ClockLink output 4 from the 931 Controller to the ClockLink
input of the right channel 921 Mono Decoding Computer.